Fully Automated AC/DC Hipot,
Insulation Resistance and More
Unbeatable Value Pricing
Vitrek's new V60 Series Electrical
Safety Testers have just made the
process of obtaining an automated
multi-function electrical safety
tester a whole lot easier. These
compact, feature-rich testers are
available in three models - so you
can choose the functions you need to
get the job done, without having to
pay for the things you don't need.
And when it comes to getting job
done, the Vitrek V60 Series comes
loaded with standard features that
help you automate the task at hand.
With the built-in RS232 interface,
you can download and run test
sequences, as well as retrieve test
results and data.

If you need one of
these labels on your product, insist
that the Vitrek label is on your
Electrical Safety Tester. That's
because the Vitrek V60 Series has
been engineered and manufactured to
meet the most demanding electrical
product safety test requirements.
So, whether your job is on an
automated production line or in a
product safety engineering lab, the
V60 Series packs the performance you
need to get the job done right - at
a value price that won't break your
budget.
Not
Just a Bare Bones Hipot Tester
At
Vitrek when we talk about value and
economy in the V60 Series, we're not
talking about a low end, stripped
down tester. We've built in the
features you need at a price that
you can't afford to pass up.
Features like - one touch automatic
testing, 160 position test memory,
built-in RS232, scanner control &
PLC interfaces, digital ramp and
dwell, no load setting of min/max
trip currents, as well as full line
and load regulation. Couple these
features with high reliability,
reduced component count, VLSI
surface mount construction and it
becomes exceedingly clear that the
V60 Series should be your next
Electrical Safety Tester.
Isn't
it about time you put Vitrek's
legendary reputation for quality and
reliability to work for you?
Features/Benefits
- Fully automated testing at the
touch of a button or via RS232 &
PLC control (GPIB optional)
- Three models to choose from -
select the functions you need to
get the job done
- Available Quicktest™ test
automation software for your PC
- AC Hipot to 5kV with 40mA
- DC Hipot to 6kV with 10mA
- Insulation Resistance to 10GW with selectable 500 &
1000VDC outputs
- Ground Continuity to 0.001W
- Built-in 36 Step Test Memory
- Two 16 Channel
Scanners Optionally Available
- Built-in 160
Step Test Memory
- Programmable Ramp & Dwell Times,
Output Voltages and Limits
- Selectable Arc Detection
- Front Panel Lockout Feature
- CE Mark Certified to EN61010
- Three Year Extended Warranty
Top of Page
Specifications
AC Hipot
| Voltage
Range |
0.100kV to
5.000kV |
| Voltage
Setting |
5 Volt
Increments |
Voltage
Regulation
(Line & Load) |
1% + 5V |
| Voltage
Accuracy |
1.5% of
reading + 10V |
| Current
Sourcing |
30 to 40mA (above
500V, 180sec. max.)
0 to 29.99mA (above 500V,
continuous)
0 to 10mA (below 500V,
continuous) |
| Current
Limit Range |
0.10 to 40mA,
0.02mA/step |
| Current
Accuracy |
1.5% of
reading + 50µA |
DC Hipot (V61, V63 only)
| Voltage
Range |
0.100kV to
6.000kV |
| Voltage
Setting |
5Volt
Increments |
Voltage
Regulation
(Line & Load) |
1% + 5V |
| Voltage
Accuracy |
1.5% of
reading + 10V |
| Current
Sourcing |
0 to 10mA (above
500V, continuous)
0 to 2mA (below 500V,
continuous) |
| Current
Limit Range |
0.10 to 10mA,
0.01mA/step |
| Current
Accuracy |
1.5% of
reading + 50µA |
Insulation Resistance (V63
only)
| DC Output
Voltage |
50V / 100V
500V / 1000V |
| Resistance
Accuracy 50V / 100V |
1 to
50MW: 5% of reading
51 to 200MW:
10% of reading
201 to 1990MW:
20% of reading |
| Resistance
Accuracy 500V / 10V |
1 to
500MW: 5% of reading
501 to 2000MW:
10% of reading
2001 to9990MW:
20% of reading |
Continuity Measurement
| Test
Current |
100mA |
| Resistance
Range |
0.001 to
1.500W |
| Resistance
Accuracy |
±0.075W |
General
| Test
Database |
10 test
sequences with up to 16
steps per test sequence |
| Front
Panel Lockout |
Prevents
database edit while in
lockout mode |
| Arc Detect |
40 level (1
to 40mA) |
| Serial
Port |
9600 Baud,
fully bi-directional RS232
interface with PC cable
included |
| GPIB |
Option GP-60,
IEEE-488 interface |
| PLC
Interface |
9-pin D-sub
connector with outputs of
Testing, Pass, Fail and
inputs of Start, Reset.
Output isolation is 400V
with 130mA continuous load
current |
| Scanner
Interface |
Control port
for V16 and V17 HV Scanners |
| Timer
Accuracy |
0.25% ± 50mS |
| Power
Source |
AC 100V,
120V, 220V, 230V at ± 10%
50/60Hz |
| Operating
Environment |
Indoor use,
altitude up to 6500ft
(2000m). Installation
Category II. Pollution
Degree 2 |
| Operating
Temperature |
0°C to 40°C,
80% RH max |
| Storage
Temperature |
-10°C to
70°C, 70% RH max |
| Dimensions |
17.6"L x 13"W x 5.9"H)
446L x 330W x 149H mm |
| Weight |
30 lbs (14kg) Net, 34 lbs
(16 kg) Ship |
| Accessories |
NIST
certification, TL-20-60
Alligator Test Leads, serial
interface cable, instruction
manual and power cord |
| Accuracy |
Stated
specifications apply for one
year at 23°C ± 5°C |
| Calibration |
ANSI/NCSL
Z540 Certificate of
calibration, with data,
traceable to NIST provided |
| Compliance |
CE Mark
Certified to EN61010 and EMC
directive EN50081-1 &
EN50082-2 |
| Warranty |
3 year
extended warranty with
registration and annual
factory calibration. 1 year
parts and labor standard. |
QuickTest™ Software
Option QT-60: Test automation
software. Easy to load graphical
test sequence development and
operating environment. Provides
time/date, operator, test
parameters, test results and
readings for review, printout or
export to database program.
|